ASSESSMENT OF MECHANICAL CHARACTERISTICS OF VASCULAR ENDO-PROSTHESES
https://doi.org/10.21122/2227-1031-2017-16-5-400-406
Abstract
Titanium nickelide (nitinol) is one of prospective materials for production of special endo-prostheses and other parts and characterized with effect of shape memory. A specific feature of vascular endo-prostheses is the necessity to provide the required rigidity within the temperature interval from 15 to 42 оС. It has been established that titanium nickelide is able to provide the required rigidity but it depends on preliminary heat treatment parameters. So, it is important to determine rela-tions between rigidity of titanium nickelide wire and its preliminary heat treatment parameters for the given temperature in-terval. The aim of the work is to create devices that allow to estimate radial and flexural rigidity of elements made of flexible nitinol wire for manufacturing various medical products, including endo-prostheses of vessels – stents and stent grafts, filter traps. Laboratory digital scales and a specially developed dynamometer based on a cylindrical slotted spring and inductive displacement transducer have been used for measuring a load. The paper proposes possible variants of device designs used to monitor radial rigidity of blood vessel endo-prostheses, as well as to control flexural rigidity of endo-prosthesis elements and wire for their manufacture. The developed devices allow us to evaluate mechanical characteristics of samples under the desired temperature conditions. An introduction of the developed devices has permitted to carry out an operative control on radial and flexural stiffness of intravascular endo-prostheses elements both under conditions of research investigations and during technological process of their manufacture. Currently, the devices are used to specify heat treatment regimes for nitin-ol wire from various manufacturers while manufacturing vascular endo-prostheses.
About the Authors
V. T. MinchenyaBelarus
Address for correspondence: Minchenya Vladimir Т. – Belarusian National Technical University, 22 Ya. Kolasа str., 220013, Minsk, Republic of Belarus. Tel.: +375 17 292-40-81 v.minchenya@bntu.by
A. L. Savchenko
Belarus
Associate Professor, PhD in Engineering
N. T. Minchenya
Belarus
Associate Professor, PhD in Engineering
References
1. Holmes D. R., Berger P., Garratt K., Bell M., Bresnahan J. (1995) Stenting in Cardiac Interventional Practice, Off-Label Versus Approved Indication. Circulation, 92 (l), 1–85.
2. Gjunter V. E., Hodorenko V. N., Jasenchuk Ju. F., Che-kalkin T. L., Ovcharenko V. V., Klopotov A. A., Damba- ev G. C., Sysoljatin P. G., Fomichev N. G., Olesova V. N., Mirgazizov M. Z., Proskurin A. V., Zigan'shin R. V., Polenichkin V. K., Matjunin A. N., Fatjushin M. Ju., Mol-chanov N. A., Monogenov A .N. (2006) Titanium Nicke- lide. Medical Material of New Generation. Tomsk: “MITs” Publishing House. 296 (in Russian).
3. Hodgson D. E., Brown J. W. (2000) Using Nitinol Alloys. Report of Shape Memory Applications Inc. 35.
4. Hodgson D. E. (2000) Fabrication, Heat Treatment and Joining of Nitinol Components. Russell S.M., Pelton A. (eds.) Proceedings of the International Conference on Shape Memory and Superelastic Technologies SMST-2000. Pa-cific Grove, California, 11–24.
5. Ming H. Wu. (2002) Fabrication of Nitinol Materials and Components. Materials Science Forum, 394–395, 285–292. DOI: 10.4028/www.scientific.net/msf.394-395.285.
6. Rubanik V. V., Milyukina S. N., Rubanik V. V. (Jr) (2008) Optimization of Thermal Treatment Modes for TiNi Wire of Medical Purpose. Sbornik Dokladov 8-i Mezhdunarod-noi Konferentsii “Avangardnye Mashinostroitel'nye Tekh- nologii”, Bolgariya, 18–20 Iyunya 2008 g. [Collected Presentations, of the 8th International Conference “Avant-garde Engineering Technologies”, Bulgaria, June 18–20, 2008]. Kranevo, 199–203 (in Russian).
7. Case L., Kreiner Z., Redmond J., Trease B. (2004) Shape Memory Alloy Shape Training Tutorial. A Teacher's Gui- de to Teaching Shape Memory Alloy Shape Training. ME559 – Smart Materials and Structures, University of Michigan. Available at: http://www-personal.umich.edu/~ btrease/share/SMA-Shape-Training-Tutorial.pdf.
8. Minchenya V. T., Stepanenko D. A., Savchenko A. L., Minchenya N. T., Chigarev A. V., Ostrovskii Yu. P., Shket A. P. (2012) Development of Methodology for Evaluation of Radial Rigidity of Endovascular Stentgrafts. Teoreticheskaya i Prikladnaya Mekhanika: Mezhdunar. Nauch.-Tekhn. Sb. [Theoretical and Applied Mechanics: International Scientific and Technical Collection of Works]. Minsk, Belarusian National Technical University, Is. 27, 137–141 (in Russian).
9. Minchenya V. T., Minchenya N. T., Savchenko A. L., Reut I. V. (2008) Complex for Measuring Parameters of Flexible Waveguides. Metrologiya i Priborostroenie = Metrology and Instrumentation, (4), 33–36 (in Russian).
10. Man'shin G. G., Minchenya V. T., Adzerikho I. E., Asi-mov R. M., Minchenya N. T., Savchenko A. L. (2013) Measuring Complex for Control of Flexible Waveguide Parameters. Problemy Sozdaniya Informatsionnykh Tekhnologii: Sb. Nauch. Trudov [Problems Pertaining to Development of Information Technologies: Collection of Scientific Works]. Moscow, Publishing House “Tekh- poligraphtsentr”, Is. 23, 70–75 (in Russian).
Review
For citations:
Minchenya V.T., Savchenko A.L., Minchenya N.T. ASSESSMENT OF MECHANICAL CHARACTERISTICS OF VASCULAR ENDO-PROSTHESES. Science & Technique. 2017;16(5):400-406. (In Russ.) https://doi.org/10.21122/2227-1031-2017-16-5-400-406